Panasonic Communication Systems KX-TDA Digital Hybrid IP-PBX Systems & Voice Processing Systems. |
|---|
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
|
|---|---|---|---|---|
| Units | Weight | |||
|
******IMPORTANT****** The KX-TDA50, KX-TDA100 and the KX-TDA200 are certified dealer models. These models must be activated prior to installation. Only dealers who have successfully completed the KX-TDA Technical Training course and have been issued a valid KX-TDA certification number can activate these systems. For detailed information on how to register a system please visit the B2B web site. If you are interested in becoming KX-TDA certified dealer, please contact your favorite Panasonic distributor. |
||||
| KX-TDA50 |
CONTROL UNIT The KX-TDA50 control unit is initially configured with 4 Super Hybrid Extension Ports and 4 Loop Start CO ports (1 LCOT card), Power Supply, RS-232 port, USB port, MOH port, Paging port and a SD card. The system is expandable to 8 COs and 24 Extension ports. Please refer to the KX-TDA50 Capacities Chart #5. Features |
1 | 9.03 lbs. | 85076-1 |
| KX-TDA100 |
CONTROL UNIT Maximum Capacity 96 ports Contains: 1 Cabinet with 5 Free Slots 1 Main Processor Unit– (Power Supply Not Included; See page 3) 1 SD Card
Features |
1 | 18.5 lbs. | 85018-1 |
| KX-TDA200 |
CONTROL UNIT Maximum Capacity 192 ports Contains: 1 Cabinet with 10 Free Slots 1 Main Processor Unit– (Power Supply Not Included; See page 3) 1 SD Card
Features |
1 | 25.4 lbs. | 85019-8 |
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
||
|---|---|---|---|---|---|
| Units | Weight | ||||
| MOUNTING HARDWARE FOR KX-TDA CONTROL UNITS | |||||
| KX-A244 |
19” BRACKET FOR THE KX-TDA50 For mounting the KX-TDA50 cabinet in a 19” rack. |
1 | 3.85 lbs. | 85112-6 | |
| KX-A243 |
19” Bracket for the KX-TDA100 For mounting the KX-TDA100 cabinet in a 19” rack. |
1 | 2.46 lbs. | 85111-9 | |
| KX-A242 |
19” BRACKET FOR THE KX-TDA200 For mounting the KX-TDA200 cabinet in a 19” rack. |
1 | 1.52 lbs. | 85110-2 | |
| KX-TDA100 & KX-TDA200 SYSTEM POWER SUPPLIES (1 REQUIRED PER SYSTEM) | |||||
| KX-TDA0103 |
L-TYPE POWER SUPPLY Large plug in system power supply for use in the KX-TDA200 basic shelf. To determine the correct size power supply for your application, please refer to the Power Supply Sizing Chart #1. |
1 | 7.58 lbs. | 85020-4 | |
| KX-TDA0104 |
M-TYPE POWER SUPPLY Medium plug in system power supply for use in the KX-TDA100 or KX-TDA200 basic shelf. To determine the correct size power supply for your application, please refer to the Power Supply Sizing Chart #1. |
1 | 6.92 lbs. | 85021-1 | |
| KX-TDA0108 |
S-TYPE POWER SUPPLY Small plug in system power supply for use in the KX-TDA100 basic shelf. To determine the correct size power supply for your application, please refer to the Power Supply Sizing Chart #1. |
1 | 5.82 lbs. | 85028-8 | |
| KX-TDA100 & KX-TDA200 EXPANSION CARDS AND ACCESSORIES | |||||
| KX-TDA100/200 STATION CARDS | |||||
| KX-TDA0143 |
4-PORT CELL STATION INTERFACE CARD (CSIF4) Required for multi-cell operation when using the (KX-TDA0142) 3-channel Cell Station. Supports up to 4 (KX-TDA0142) Cell Station. One card requires one free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 1.06 lbs. | 85119-5 | |
| KX-TDA0144 |
8-PORT CELL STATION INTERFACE CARD (CSIF8) Required for multi-cell operation when using the (KX-TDA0142) 3-channel Cell Station. Supports up to 8 Cell Stations (KX-TDA0142). 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 3.81 lbs. | 85024-2 | |
| KX-TDA0170 |
8-PORT DIGITAL HYBRID LINE CARD (DHLC8) 8 ports per card. Supports KX-T7600, KX-T7400 (DPT), KX-T7700 (APT) series telephones. Single Line (SLT), DSS console and KX-T0141, 2 Port Cell Station. 2 ports provide power failure transfer. 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 4.45 lbs. | 85027-3 | |
| KX-TDA0171 |
8-PORT DIGITAL LINE CARD (DLC8) 8 ports per card. Supports KX-T7600 and KX-T7400 series telephone (DPT), DSS console and KX-T0141, 2 Port Cell Station. 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 4.92 lbs. | 85028-0 | |
| KX-TDA0172 |
16-PORT DIGITAL LINE CARD (DLC16) 16 ports per card. Support KX-T7600 and KX-T7400 series (DPT) Telephones, DSS consoles and KX-T0141, 2 Port Cell Station. 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 4.32 lbs. | 85029-7 | |
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
|
|---|---|---|---|---|
| Units | Weight | |||
| KX-TDA100/200 STATION CARDS (Continued) | ||||
| KX-TDA0173 |
8-PORT SINGLE LINE CARD (SLC8) 8 ports per card. Supports single line telephones (SLT). 2 ports are equipped with power failure transfer and 8 DTMF receivers. 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 4.10 lbs. | 85030-3 |
| KX-TDA0174 |
16-PORT SINGLE LINE CARD (SLC16) 16 ports per card. Supports single line telephones (SLT). 4 ports are equipped with power failure transfer and 16 DTMF receivers. 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 4.38 lbs. | 85031-0 |
| KX-TDA0175 |
16-PORT SINGLE LINE CARD WITH MESSAGE WAITING (MSLC16) 16 ports per card. Supports Single Line Telephones with and without Message waiting lights. 4 ports are equipped with power failure transfer. Also equipped with 16 DTMF receivers. 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 4.69 lbs. | 85032-7 |
| KX-TDA0470 |
16-CHANNEL IP EXTENSION CARD (IP - EXT16) The KX-TDA0470 is required when using IP Telephones (KX-NT136). Each KX-TDA0470 card requires one free slot and supports up to 16 KX-NT136 IP extensions. A maximum of 4 cards can be installed in the KX-TDA100 and 8 can be installed in the KX-TDA200. Please refer to System Capacities Chart# 2 & 3 prior to configuring a system. |
1 | 1.10 lbs. | 85128-7 |
| KX-TDA0180 |
8-PORT LOOP START CO TRUNK CARD (LCOT8) 8 ports per card. 2 ports have power failure transfer. 1 card requires 1 free slot. 1 optional (KX-TDA0193) 8 port caller ID card can be mounted to support caller ID. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 4.14 lbs. | 85033-4 |
| KX-TDA0181 |
16-PORT LOOP START CO TRUNK CARD (LCOT16) 16 ports per card. 4 ports have power failure transfer. 1 card requires 1 free slot. Up to two optional (KX-TDA0193) 8 port caller ID cards can be mounted to support caller ID. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 4.25 lbs. | 85034-1 |
| KX-TDA0187 |
T1 TRUNK CARD (T1) 24 ports per card. Channels assignable as LCO, GCO, DID, OPX or TIE (E&M). ANI and DID Supported. External Channel Service Unit (CSU) required. 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 3.46 lbs. | 85036-5 |
| KX-TDA0290 |
ISDN PRIMARY RATE INTERFACE (PRI 23) 23 ports per card. 23 B channels + 1 D channel. External Channel Service Unit (CSU) required. 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 3.48 lbs. | 85041-9 |
| KX-TDA0484 |
4-CHANNEL IP GATEWAY CARD (IP-GW4) Supports up to 4 IP connections for TDA system networking. H.323V.2, ITU-T, G.711 G729a and G.723.1 compliant. Web programming LAN interface 10 base T/100BASE T. 1 card requires 1 free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
1 | 1.79 lbs. | 85120-1 |
| KX-TDA0490 |
16-CHANNEL IP GATEWAY CARD (IP GW16) Supports up to 16 IP connections for TDA system networking. H. 323V.2, ITU-T, G711, G729a and G.723.1 compliant. 1 card requires 1 free slot. Please refer to system capacities chart # 2 & 3 prior to configuring a system. |
1 | 1.20 lbs. | 85129-4 |
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
|
|---|---|---|---|---|
| Units | Weight | |||
| KX-TDA100/200 RESOURCE AND FEATURE CARDS | ||||
| KX-A258 |
BLANK SLOT COVER Optional metal panel to cover unused free slots. One panel covers one slot. 5 panels per package. |
3 | 3.48 lbs. | 85066-2 |
| KX-TDA0105 |
MEMORY EXPANSION CARD (MEC) FOR TDA100/200 For use with the KX-TDA100/200 only with version 1.1 or higher software. Required when double capacity DXDP is used. Please refer to the Memory Expansion Requirements Chart #6 |
3 | 0.33 lbs. | 85118-8 |
| KX-TDA0190 |
OPTIONAL 3-SLOT BASE CARD (OPB3) This card is equipped with 3 connectors to receive the following option cards: 4 Channel Message Card (MSG4), 4-Port Doorphone Card (DPH4), and the 16-Port Echo Cancellation Card (ECHO16). Requires 1 slot. Mounts in the optional card slot or a free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 3.46 lbs. | 85037-2 |
| KX-TDA0191 |
4-CHANNEL MESSAGE CARD (MSG4) Provides 4 ports for outgoing messages for DISA, Queuing, Wake-Up and internal hold melody. A maximum of 64 messages can be recorded with a maximum total recording time of 8 minutes. Mounted on the KX-TDA0190 (OPB3) card. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 1.43 lbs. | 85038-9 |
| KX-TDA0161 |
4-PORT DOORPHONE CARD (DPH4) Required to connect doorphones (KX-T30865 and KX-T7775). Supports up to 4 doorphones and door opener relays. Mounts on the KX-TDA0190 (OPB3) card. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 1.65 lbs. | 85025-9 |
| KX-TDA0164 |
4 EIO CARD (EIO4) Mounts on the KX-TDA0190 Optional 3-Slot Base card (OPB3). Contains 4 dry contact that allows you to control external devises such as a door strike or an automatic garage door-opener. You can also connect up to 4 external sensor devises. |
3 | .44 lbs. | 85126-3 |
| KX-TDA0166 |
16-PORT ECHO CANCELLATION CARD (ECHO16) Provides echo cancellation for conference calls for up to 16 ports. Mounts on the KX-TDA0190 (OPB3) card. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 1.36 lbs. | 85026-6 |
| KX-TDA0410 |
CTI LINK CARD Ethernet card for CTI communications via 10Base T for programming using LAN or WAN. Contains one RJ-45 connector. One card requires 1 slot. Mounts in the optional card slot or a free slot. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 3.41 lbs. | 85044-0 |
| KX-TDA0196 |
REMOTE CARD Analog modem card for remote communication. V.90 support. Mounts on the main processor card (MPR) Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 1.23 lbs. | 85040-2 |
| KX-TDA0168 |
SINGLE LINE EXTENSION CALLER CARD (SLT CID) Mounts on the KX-TDA0173 8 Port Single Line Extension Card (SLC8) only. Allows the system to pass caller ID information to single line devices. Requires TDA version 2 software or higher. Supports Bell/ETSI FSK only |
3 | .33 lbs. | 85127-0 |
| KX-TDA0193 |
8-PORT CALLER ID CARD (CID8) Required to receive Caller ID information from the CO. Each KXTDA0193 activates caller ID on 8 CO lines. Mounts on the KX-TDA0180 and KX-TDA0181 Loop Start CO Cards. Please refer to System Capacities Chart #2 prior to configuring a system. |
3 | 1.47 lbs. | 85039-6 |
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
|
|---|---|---|---|---|
| Units | Weight | |||
| KX-TDA50 EXPANSION CARDS AND ACCESSORIES | ||||
| KX-TDA50 STATION CARDS | ||||
| KX-TDA5170 |
4-PORT HYBRID LINE CARD (HLC4) 4 ports per card. Supports KX-T7700 (APT) series telephones, Single Line (SLT) and DSS console, (KX-T0141) 2 port Cell Station and Voice Mail. Maximum one per system. Please refer to KX-TDA50 System Capacities Chart #5 prior to configuring a system. |
5 | 4.4 lbs. | 85080-8 |
| KX-TDA5171 |
4-PORT DIGITAL LINE CARD (DLC4) 4 ports per card. Supports KX-T7600, KX-T7400(DPT) series telephones, DSS console, (KX-T0141) 2 port Cell Station and Voice Mail. Maximum one per system. Please refer to KX-TDA50 System Capacities Chart #5 prior to configuring a system. |
5 | 4.07 lbs. | 85081-5 |
| KX-TDA5172 |
8-PORT DIGITAL LINE CARD (DLC8) 8 ports per card. Supports KX-T7600 & KX-T7400 (DPT) series telephones, DSS console, (KX-T0141) 2 port Cell Station and Voice Mail. Maximum two per system. Please refer to KX-TDA50 System Capacities Chart #5 prior to configuring a system. |
5 | 5.18 lbs. | 85082-2 |
| KX-TDA5173 |
4-PORT SINGLE LINE CARD (SLC4) 4 ports per card. Supports single line telephones (SLT). Also equipped with 4 DTMF receivers. 1 card max per system. Please refer to KXTDA50 System Capacities Chart #5 prior to configuring a system. |
5 | 4.07 lbs. | 85083-9 |
| KX-TDA5174 |
8-PORT SINGLE LINE CARD (SLC8) 4 ports per card. Supports single line telephones (SLT). Also equipped with 8 DTMF receivers. 2 cards max per system. Please refer to KXTDA50 System Capacities Chart #5 prior to configuring a system. |
5 | 5.18 lbs. | 85084-6 |
| KX-TDA5175 |
4-PORT PROPRIETARY LINE CARD (PLC4) 4 ports per card. Supports KX-T7700 series (APT), DSS and Voice Mail. 1 card max per system. Please refer to KX-TDA50 System Capacities Chart #5 prior to configuring a system. |
5 | 4.41 lbs. | 85085-3 |
| KX-TDA5176 |
8-PORT PROPRIETARY EXTENSION CARD (PLC8) 8 ports per card. Supports KX-T7700 Series (APT), DSS and Voice Mail. 2 cards max per system. Please refer to KX-TDA50 System Capacities Chart #5 prior to configuring a system. |
5 | 5.1 lbs. | 85086-0 |
| KX-TDA50 CENTRAL OFFICE CARDS | ||||
| KX-TDA5180 |
4-PORT LOOP START CO CARD (LCOT4) 4 ports per card. 2 ports have power failure transfer. 1 optional (KXTDA5193) 4 port caller ID can be mounted to support caller ID. Please refer to KX-TDA50 System Capacities Chart #5 prior to configuring a system. |
5 | 4.4 lbs. | 85087-7 |
| KX-TDA5480 |
VOIP GATEWAY CARD (IPGW4) Supports up to 4 IP connections for networking the KX-TDA50 to other KX-TDA systems. H.323V.2, ITU-T, G729a, G.723.1 and G711 compliant. 1 card max per system. Please refer to KX-TDA50 System Capacities Chart #5 prior to configuring a system. |
1 | 4.07 lbs. | 85091-4 |
| KX-TDA50 ACCESSORIES | ||||
| KX-TDA5105 |
MEMORY EXPANSION CARD (MEC) FOR TDA50 For use with the KX-TDA50 only with version 1.1 or higher software. Required when DXDP is used. Please refer to the Memory Expansion Requirements Chart #7 |
5 | 0.11 lbs. | 85121-8 |
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
|
|---|---|---|---|---|
| Units | Weight | |||
| KX-TDA50 ACCESSORIES (Continued) | ||||
| KX-TDA5161 |
4-PORT DOORPHONE / DOOR OPENER CARD (DPH4) Support up to 4 doorphones (KX-T30865 or KX-T7775). Also equipped with 4 dry contacts for connection to electric door strike or other compatible type equipment. Maximum 1 per system. |
5 | 6.3 lbs. | 85077-8 |
| KX-TDA5166 |
8-CHANNEL ECHO CANCELLER CARD (ECHO8) Provides echo cancellation for conference calls for up to 16 ports. Max 1 per system |
5 | 3.85 lbs. | 85078-5 |
| KX-TDA5168 |
EXTENSION CALLER ID CARD (EXT-CID) Required to pass Caller ID to Single line telephone, fax answering machines etc. Supports up to 8 SLT devises. One card per system. Mounts in any of the optional slots. |
5 | 3.85 lbs. | 85079-2 |
| KX-TDA5193 |
4-PORT CALLER ID CARD (CID4) Required to receive Caller ID information from the CO. Each KXTDA5193 activates caller ID on 4 CO lines. Mounts on the KX-TDA5180 Loop Start CO Card. |
5 | 1.10 lbs. | 85089-1 |
| KX-TDA5196 |
REMOTE CARD (V.90) (RMT) Modem card for remote maintenance and programming. Maximum 1 per systems |
5 | .881 lbs. | 85090-7 |
| KX-A236 |
ADDITIONAL AC POWER SUPPLY Optional external power supply required when over 4 KX-T7000, 7200, 7300, 7400, 7700 series telephones and over 4 KX-T0141 Cell Stations are installed. Please refer to the KX-TDA50 Capacities Chart #5 |
5 | 9.92 lbs. | 85092-1 |
| KX-TDA5191 |
2-CHANNEL MESSAGE CARD (MSG2) Provides 2 ports for outgoing messages for DISA, Queuing, Wake-Up and internal hold melody. A maximum of 32 messages can be recorded with a maximum total recording time of 8 minutes. |
5 | 3.85 lbs. | 85088-4 |
| OPTIONAL SOFTWARE | ||||
| KX-TDA0350 |
PC PHONE SOFTWARE Software to make a PC emulate as a TDA telephone/extension. Includes 5 user licenses. Requires KX-T7601 USB Expansion Module. |
1 | 1.69 lbs. | 85043-3 |
| KX-TDA0920 |
CTI/NETWORK SYSTEM APPLICATION SOFTWARE FOR TDA100/200 SD Card that contains software to support Enhanced CTI functions and network DSS/BLF operation. Requires version 2.0 software. |
3 | .32 lbs. | 85133-1 |
| KX-TDA5920 |
CTI/NETWORK SYSTEM APPLICATION SOFTWARE FOR TDA50 SD Card that contains software to support Enhanced CTI functions and network DSS/BLF operation. Requires version 2.0 software. |
3 | .32 lbs. | 85133-1 |
| MULTI-CELL WIRELESS | ||||
| KX-T0141 |
2-CHANNEL CELL STATION (CS) 2 port cell station for use with multi-cell wireless feature in the KX-TDA50, 100 and 200. The KX-T0141 connects directly to an extension port, compatible with DHLC8, DHLC16 and HLC4 cards in the KX-TDA 100/200 and the 4 initial Super Hybrid Ports, DLC4 and DLC8 cards in the KX-TDA50. Please refer to Charts #2 and #5 for maximum capacity information. |
5 | 2.86 lbs. | 85093-8 |
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
|
|---|---|---|---|---|
| Units | Weight | |||
| MULTI-CELL WIRELESS (Continued) | ||||
| KX-TDA0142 | 3-CHANNEL HIGH DENSITY CELL STATION (CS) 3-port cell station unit ** For use with KX-TDA100, KX-TDA200 ONLY ** Requires the KX-TDA0144 8-port Cell Station or the KX-TDA0143 4 port Cell Station Interface card. Required for multi-cell wireless operation. Recommended for high user multi cell wireless TDA systems. Suggested for larger premise (longer distance) installations. | 3 | 3.74 lbs. | 85023-5 |
|
KX-TD7690 Backlit LCD Display |
2.4GHZ EXECUTIVE WIRELESS HANDSET 5-Line LCD with Back-Light • Navi-key operation • Supports PBX Functionality • Headset Jack • Speakerphone • Vibrator Ringing • Auto Answer |
3 | 5.31 lbs. | 85060-0 |
|
|
||||
|
KX-TD7680 |
2.4GHZ WIRELESS HANDSET 3-Line LCD with Back-Light • Navi-key Operation • Supports PBX Functionality • Headset Jack • Speakerphone • Vibrator Ringing • Auto Answer |
3 | 4.51 lbs. | 85067-9 |
|
|
||||
| KX-A264 | CARRYING CASE FOR KX-TD7680 Black, carrying case with belt clip for the KX-TD7680. | 6 | 0.91 lbs. | 85113-3 |
| KX-A269 | CARRYING CASE FOR KX-TD7690 Black carrying case with belt clip for the KX-TD7690. | 12 | 1.55 lbs. | 85065-5 |
| PSZZTD142CE | SITE SURVEY CELL STATION BATTERY PACK Used to power the KX-TDA0142 or the KX-T0141 Cell Station, making it portable. The Cell Station, along with a KX-TD7680 or a KXTD7690 can be used as a site survey tool to assist the installer in determining coverage and the placement of the cell stations. Requires 1 PSZZ1TD0142 power supply adapter. Must be purchased from the Panasonic Parts Center at: 800-833-9626. | N/A | N/A | N/A |
| PSZZ1TDA0142 | BATTERY PACK CELL STATION CONNECTOR Consists of a connector to connect the Cell Station battery pack to Cell Station when doing site surveys. 1 required with the Cell Station Battery Pack Must be purchased from the Panasonic Parts Center at: 800-833-9626. | N/A | N/A | N/A |
| PROPRIETARY WIRELESS TELEPHONES | ||||
|
KX-T7885
KX-T7885-W
|
PROPRIETARY WIRELESS MULTI-LINE TELEPHONE WITH BACKLIT LCD DISPLAY Operation Frequency 902-928 MHz • 12 CO Line Capability • 3-Line Multifunction Backlit LCD Display • Message Waiting • Caller ID (APITS) • Headset Jack • Programmable Ringing or Vibrator • Dual Mode (SLT or APITS) • 30-Channel Auto Scanning • Separate Charging Unit • Remote Locatable Antenna • One Long Life, Fast Charge Nickel-Metal Hydride Battery Included. |
3 | 11.4 lbs. | 82591-2 |
| White | ||||
| Backlit LCD Display | KX-T7885-W: WHITE VERSION | 3 | 11.4 lbs. | 82630-8 |
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
|
|---|---|---|---|---|
| Units | Weight | |||
| PROPRIETARY WIRELESS TELEPHONES (Continued) | ||||
|
KX-TD7895 KX-TD7895-W |
DIGITAL SPREAD SPECTRUM (SST) MULTI-LINE TELEPHONE 900 MHz Spread Spectrum Technology (SST) | 1 | 10.6 lbs. | 82610-0 |
|
• 2 Modes (APITS and SLT) • 3-Line Multifunction Backlit LCD Display |
||||
|
• 25-Channel Auto Scanning • 12 Programmable Line/Feature Buttons (APITS Mode) |
||||
|
• Separate Charging Unit • Separate Wall Mountable Base Antenna • Headset Jack • Programmable Ring or Vibrator |
||||
| • One Nickel Metal Hydride Battery Included. | ||||
| White | ||||
| Backlit LCD Display | KX-TD7895-W: WHITE VERSION | 1 | 10.6 lbs. | 82682-7 |
| KX-A276 | 3.6 VOLT NICKEL METAL HYDRIDE BATTERY For use with the KX-T7885 | 3 | 1.9 lbs. | 82593-6 |
| KX-A276-W | 3.6 VOLT NICKEL METAL HYDRIDE BATTERY For use with the KX-T7885 | 3 | 1.9 lbs. | 82631-5 |
| IP TELEPHONES | ||||
| KX-NT136 | IP TELEPHONE | 3 | 3.46 lbs. | 85130-0 |
| KX-NT136-B | Equipped with a 6 line backlit LCD display, 24 Programmable buttons, | |||
| 12 fixed buttons for (Intercom, Conference, Pause, Forward/Do Not | ||||
| Disturb, Flash/Recall, Auto Answer/Mute, Auto Dial/Store, Hold, | ||||
| Transfer, Message, Redial, Flash/Recall and Speakerphone). Also | ||||
| equipped with a Navigation Key, Headset Jack and can be Wall | ||||
| Mounted. The KX-NT136 IP telephone can only be connected to a | ||||
| managed wide a or local area network. Requires KX-TDA0470 16 | ||||
| channel IP extension card to be installed in KX-TDA100 or KX-TDA200 | ||||
| and connected to the same network. The KX-NT136 can be powered through the LAN (POE) or an optional power adaptor KX-A237 (sold | ||||
| Black | ||||
| separately) Please refer to Chart # 2 & 3 prior to configuring a system. | 3 | 3.46 lbs. | 85131-7 | |
| KX-A237 | AC ADAPTOR for the KX-NT136 | 3 | .84 lbs. | 85132-4 |
| Includes one adaptor for use with one KX-NT136 IP telephone. | ||||
| Required if power is not supplied over the network (POE). | ||||
| KX-T7600 SERIES TELEPHONES | ||||
|
KX-T7601 KX-T7601-B |
USB EXPANSION MODULE For connecting the KX-T7636 and KX-T7633 telephones to a PC. Required for use with PC Phone Software KX-TDA350. Included with the module is a 6’ USB cable and a CD containing a 90 day free trial KX-TDA350 PC Phone Software. Max of one USB module | 5 | 3.52 lbs. | 85046-4 |
| per telephone. | ||||
| Black | ||||
| KX-T7601-B: BLACK VERSION | 5 | 3.52 lbs. | 85047-1 | |
|
KX-T7603 KX-T7603-B |
12 KEY ADD-ON MODULE Attaches to the KX-T7636 and KX-T7633 telephones. • Adds an additional 12 CO keys/feature keys. • Only one can be added per telephone. |
3 | 3.13 lbs. | 85048-8 |
|
Black |
||||
| KX-T7603-B: BLACK VERSION | 3 | 3.13 lbs. | 85049-5 | |
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
|
|---|---|---|---|---|
| Units | Weight | |||
| KX-T7600 SERIES TELEPHONES (Continued) | ||||
|
KX-T7625 KX-T7625-B |
DIGITAL 24-BUTTON SPEAKERPHONE Proprietary Telephone |
3 | 10.1 lbs. | 85050-1 |
| Black | ||||
| KX-T7625-B: BLACK VERSION | 3 | 10.1 lbs. | 85051-8 | |
|
KX-T7630 |
DIGITAL 24-BUTTON 3-LINE LCD SPEAKERPHONE
PROPRIETARY TELEPHONE |
3 | 10.4 lbs. | 85052-5 |
|
• 24 programmable CO keys with dual color LED
• Navigator key • Headset jack |
||||
| Black | ||||
| KX-T7630-B: BLACK VERSION | 3 | 10.4 lbs. | 85053-2 | |
| KX-T7633 | DIGITAL 24-BUTTON 3-LINE BACKLIT LCD SPEAKERPHONE | 3 | 10.4 lbs. | 85054-9 |
| KX-T7633-B |
PROPRIETARY TELEPHONE • 3line x 24-character back-light LCD Display • 24 programmable CO keys with dual color LED • Navigator key • Hands-free speakerphone • Large message/ringing lamp (red/green) • Headset jack • Compatible with optional 12-CO keys interface (KX-T7603). • XDP/DXDP Jack for adding another KX-T7600 DPITS or SLT extension |
|||
| Black | ||||
| Backlit LCD Display | KX-T7633-B: BLACK VERSION | 3 | 10.4 lbs. | 85055-6 |
| KX-T7636 | DIGITAL 24-BUTTON BACKLIT LCD SPEAKERPHONE | 3 | 10.4 lbs. | 85056-3 |
| KX-T7636-B |
PROPRIETARY TELEPHONE • 6line x 24-character back-light LCD Display |
|||
| • 24 programmable CO keys with dual color LED | ||||
| • Navigator key | ||||
| • Hands-free speakerphone | ||||
| • Large message/ringing lamp (red/green) | ||||
| • Headset jack | ||||
| • Compatible with optional 12-CO keys interface (KX-T7603). | ||||
| • XDP/DXDP Jack for adding another KX-T7600 DPITS or SLT extension | ||||
| Black | ||||
| Backlit LCD Display | KX-T7636-B: BLACK VERSION | 3 | 10.4 lbs. | 85057-0 |
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
||
|---|---|---|---|---|---|
| Units | Weight | ||||
| KX-T7600 SERIES TELEPHONES (Continued) | |||||
|
KX-T7640 KX-T7640-B |
DIGITAL DSS CONSOLE (60-DSS) • 60 Direct Station Selection (DSS)/Busy Lamp Field (BLF) • Wall mountable • Physically attached to Digital System Telephone by a screw (A DSS Console requires 1 Digital System Telephone extension port) • No restrictions for programmable Flex Keys • For all T7600 series models
|
3 | 7.29 lbs. | 85058-7 | |
| Black | |||||
| KX-T7640-B: BLACK VERSION | 3 | 7.29 lbs. | 85059-0 | ||
| KX-T7700 SERIES HYBRID SYSTEM TELEPHONES | |||||
| KX-T7750 | 24 BUTTON MONITOR TELEPHONE | 3 | 1.28 lbs. | 50136-0 | |
|
KX-T7750-B |
• 24 Programmable Buttons • 12 CO & 12 Personal/Feature 10 fixed buttons for (Intercom, Conference, Program, Voice Mail, Pause, Forward/Do Not Disturb, Flash/Recall, Auto Answer/Mute, Auto Dial/Store and Redial) |
||||
|
• 3 large buttons for Hold, Transfer and Monitor. • Volume Control for Speaker, Ringer and Handset |
|||||
|
• Headset Jack • Wall Mountable |
|||||
|
Black |
|||||
| KX-T7750-B: CHARCOAL/BLACK VERSION | 3 | 1.28 lbs. | 50143-0 | ||
| KX-T7720 | 24 BUTTON SPEAKERPHONE TELEPHONE | 3 | 2.46 lbs. | 50051-0 | |
| KX-T7720-B | • 24 Programmable Buttons | ||||
| • 12 CO & 12 Personal/Feature,10 fixed buttons for (Intercom, Conference, Program, Voice Mail, Pause, Forward/Do Not Disturb, Flash/Recall, Auto Answer/Mute, Auto Dial/Store and Redial) | |||||
| • 3 large buttons for Hold, Transfer and Speakerphone, Volume Control for Speaker, Ringer and Handset | |||||
|
• Headset Jack • Wall Mountable |
|||||
|
Black |
|||||
| KX-T7720-B: CHARCOAL/BLACK VERSION | 3 | 2.46 lbs. | 50068-0 | ||
| KX-T7731 | 24 BUTTON SPEAKERPHONE TELEPHONE WITH BACKLIT DIAL | 3 | 2.56 lbs. | 85114-0 | |
| KX-T7731-B | KEYPAD AND 1 LINE BACKLIT LCD DISPLAY | ||||
| • 24 Programmable Buttons, 12 CO & 12 Personal/Feature | |||||
| • 10 Fixed Buttons for (Intercom, Conference, Program, Voice Mail, Pause, Forward/Do Not Disturb, Flash/Recall, Auto Answer/Mute, Auto Dial/Store and Redial) Plus 3 Large Buttons for Hold Transfer and Speakerphone | |||||
| • Navigation Key for Volume, Display Contrast and Function Selection, Headset Jack, Wall Mountable | |||||
| • Available in White (KX-T7731) or Charcoal/Black (KX-T7731-B) | |||||
| Backlit Dial Keypad |
Black |
||||
| & LCD Display | KX-T7731-B: CHARCOAL/BLACK VERSION | 3 | 2.56 lbs. | 85115-7 | |
|
KX-T7740
KX-T7740-B |
48 BUTTON DSS CONSOLE • 32 DSS keys w /LED’S • 16 Feature keys wo/LED’S • Wall Mountable |
3 | 1.28 lbs. | 50099-0 | |
|
Black |
|||||
| KX-T7740-B: CHARCOAL/BLACK VERSION | 3 | 1.28 lbs. | 50105-0 | ||
|
Model Number |
Description |
Per Master Carton |
UPC
Code |
|
|---|---|---|---|---|
| Units | Weight | |||
| DOOR PHONES | ||||
|
KX-T30865-W KX-T30865-B |
STANDARD DOOR PHONE Compatible with all KX-TD Digital Super Hybrid, KX-T, KX-TA Advanced Hybrid, KX-TD500 and KX-TDA Digital Hybrid IP-PBX telephone systems.
|
3 | 1.9 lbs. | 50167-0 |
| Black | ||||
| KX-T30865-B: BLACK VERSION | 3 | 1.9 lbs. | 50179-0 | |
| KX-T7775 | PREMIUM DOORPHONE Compatible with Panasonic KX-TD Digital Super Hybrid, KX-T and KX-TA Advanced Hybrid, KX-TD500 and KX-TDA Digital Hybrid IP PBX systems. Can be surface or recessed mounted in most plastic single gang electrical boxes. Optional decorative metal faceplates KX-A401, 402 & 403 can be installed. Includes doorphone and power adaptor assembly. Offers twice the wiring distance of the standard KX-T30865 doorphone. | 3 | 1.72 lbs. | 85122-5 |
| KX-A401 | POLISHED BRASS FACEPLATE Mounts over the face of the KX-T7775 premium doorphone. Includes matching mounting hardware. | 3 | .25 lbs. | 85123-2 |
| KX-A402 | BRUSHED STAINLESS STEEL FACEPLATE Mounts over the face of the KX-T7775 premium doorphone. Includes matching mounting hardware. | 3 | .25 lbs. | 85124-9 |
|
Model Number |
Description |
Per Master Carton |
UPC
Code 0379888 |
|
|---|---|---|---|---|
| Units | Weight | |||
| KX-TVA VOICE PROCESSING SYSTEM CONTROL UNITS | ||||
| KX-TVA50 |
BASIC CABINET: The KX-TVA50 is a Voice Processing system that supports both Voice Mail and Automated Attendant Service. The system can be installed using DPITS, APITS and In-band Integration. The basic cabinet is configured as follows:
• 2 ports expandable to 6 ports using ether the KX-TVA502 or the KX-TVA503 Cards • 4 hours of storage expandable to 8 hours using the KX-TVA524 • 164 Mailboxes • 1 USB port Major Features |
1 | 6.91 lbs. | 85146-1 |
| KX-TVA200 |
BASIC CABINET: The KX-TVA200 is a Voice Processing system that supports both Voice Mail and Auto Attendant services. The system can be installed using DPITS. The basic cabinet is initially configured as follows :
• 4 ports expandable to 24 ports using KX-TVA204 Cards • 1000 hours of Storage • 1024 Mailboxes • USB and RS232 ports Major Features |
1 | 12.28 lbs. | 85143-0 |
|
Model Number |
Description |
Per Master Carton |
UPC
Code 0379888 |
|
|---|---|---|---|---|
| Units | Weight | |||
| KX-TVA50 & KX-TVA200 VOICE PROCESSING SYSTEM EXPANSION AND FEATURE CARDS | ||||
| KX-TVA502 | 2 PORT DPT/APT/SLT INTERFACE CARD For use with the KX-TVA50 only. Supports DPITS, APITS and In band integration. Expands the port capacity of the system by 2 ports. A maximum of 2 cards can be installed in the KX-TVA50. | 3 | 0.61 lbs. | 85147-8 |
| KX-TVA503 | 2 PORT DPT INTERFACE CARD For use with the KX-TVA50 only. Supports DPITS integration only. Expands the port capacity of the system by 2 ports. A maximum of 2 cards can be installed in the KX-TVA50. | 3 | 0.61 lbs. | 85148-5 |
| KX-TVA524 | 4 HOUR MEMORY EXPANSION CARD For use with the KX-TVA50 only. Expands the storage capacity of the KX-TVA50 by 4 hours. Maximum of one card can be installed per system. | 3 | 0.28 lbs. | 85149-2 |
| KX-TVA594 | LAN I/F CARD FOR USE WITH THE KX-TVA50 ONLY Required to connect the KX-TVA50 to a wide or local area network Provides messaging from the TVA system to a subscribers email | 3 | 0.33 lbs. | 85150-8 |
| KX-TVA204 | 4 PORT DPT INTERFACE CARD For use with the KX-TVA200 only. Supports DPITS integration only. Expands the port capacity of the system by 4 ports. A maximum of 5 cards can be installed in the KX-TVA200. | 3 | 0.75 lbs. | 85144-7 |
| KX-TVA296 | REMOTE MODEM CARD Modem card for use in the KX-TVA50 & KX-TVA200. Required for remote programming and administration. Maximum of one per system. | 3 | 0.36 lbs. | 85145-4 |
| MOUNTING HARDWARE FOR KX-TVA CONTROL UNITS | ||||
| KX-A249 | 19" RACKMOUNT BRACKET FOR THE TVA50 For mounting the KX-TVA50 into a 19" rack. | 3 | 2.10 lbs. | 85160-7 |
| KX-A244 | 19" RACKMOUNT BRACKET FOR THE TVA200 For mounting the KX-TVA200 into a 19" rack. | 3 | 3.85 lbs. | 85112-6 |
| KX-TDA DIGITAL HYBRID IP-PBX SYSTEM FEATURE LIST | |||
|---|---|---|---|
| System Features | KX-TDA50 | KX-TDA100 | KX-TDA200 |
| Absent Message Capability | X | X | X |
| Account Code Entry (Forced Verified) | X | X | X |
| Account Code Entry (Optional) | X | X | X |
| A.R.S. (Automatic Route Selection) | X | X | X |
| Automated Attendant (with DISA/OGM) | X | X | X |
| Automatic CO Hunting | X | X | X |
| Automatic Fault Logging | X | X | X |
| B.G.M. (Back Ground Music) Jack | X | X | X |
| Call Back Busy | X | X | X |
| Call Forwarding | X | X | X |
| Call Hunting (Terminal or Circular) | X | X | X |
| Call Log | X | X | X |
| Call Parking Zones | X | X | X |
| Call Park Retrieve | X | X | X |
| Call Pick Up | X | X | X |
| Call Transfer/Transfer Recall | X | X | X |
| Call Waiting | X | X | X |
| Caller ID, Call Logging | X | X | X |
| Caller ID, Call Log Lock | X | X | X |
| Caller ID, Callback | X | X | X |
| Caller ID, Call Waiting | X | X | X |
| Caller ID, Date and Time Adjust | X | X | X |
| Caller ID (Name and/or Number) | X | X | X |
| Caller ID TO SLT | X | X | X |
| Class of Service | X | X | X |
| CO Limited Duration Timer | X | X | X |
| CO Line Names | X | X | X |
| CO Line Status (Two Color LED) | X | X | X |
| Conference Calling (8 Party) | X | X | X |
| Data Line Security (for Fax or Modem) | X | X | X |
| Data and Time Display | X | X | X |
| Delayed Ringing | X | X | X |
| D.I.L. (Direct in Line) | X | X | X |
| D.I.S.A. (Direct Inward System Access) | X | X | X |
| D.I.S.A. Single Digit Access | X | X | X |
| Distinctive Ringing Tone (CO, Intercom) | X | X | X |
| Distinctive Ring Tone (Doorphones) | X | X | X |
| D.N.D. (Do Not Disturb) | X | X | X |
| Do Not Disturb Override | X | X | X |
| Door Intercoms/Door Opener Contacts | 4 | 8 | 16 |
| DSS/BLF Consoles | X | X | X |
| Dual Port Usage (Parallel SLT Station) | X | X | X |
| Duration Time of Call Display | X | X | X |
| DXDP (Version 1.1) | X | X | X |
| Electronic Station Lock | X | X | X |
| Emergency Call Number Programming | X | X | X |
| Extension Groups | X | X | X |
| Extension Name on Display When Idle | X | X | X |
| KX-TDA DIGITAL HYBRID IP-PBX SYSTEM FEATURE LIST | |||
|---|---|---|---|
| System Features | KX-TDA50 | KX-TDA100 | KX-TDA200 |
| Executive Hold | X | X | X |
| Executive Override | X | X | X |
| Executive Override Deny | X | X | X |
| External Modem Support | X | X | X |
| External Paging Ports | X | X | X |
| External Sensor Input | X | X | |
| Flexible CO Keys (DSS/BLF, One Touch Dial) | X | X | X |
| Flexible DSS Keys (One Touch, Feature Access) | X | X | X |
| Flexible Key Assignments | X | X | X |
| Flexible Line Assignment | X | X | X |
| Flexible Night Service/Programmable/Manual | X | X | X |
| Flexible Ringing Assignment (Day, Night) | X | X | X |
| Flexible Ring Assignment (Lunch) | X | X | X |
| Flexible Station Numbering | X | X | X |
| Hands-Free Answer Back Intercom | X | X | X |
| Handset/Headset-Display Phones | X | X | X |
| Hold | X | X | X |
| Hold Recall/Hold Reminder | X | X | X |
| Hotel/Motel Features | X | X | X |
| Ring Message Waiting | X | X | X |
| Remote Station Lock | X | X | X |
| Quick Dialing | X | X | X |
| Room Status | X | X | X |
| Industry Standard Telephone Capability | X | X | X |
| Internal Paging (All Call Paging) | X | X | X |
| Internal Paging (Zone Paging) | X | X | X |
| ISDN Primary Rate Interface (PRI) with QSIG | X | X | |
| Last Number Redial | X | X | X |
| Limited Call Duration | X | X | X |
| Live Call Screening (DPITS only) | X | X | X |
| Live Call Screening, Remote (DPITS only) | X | X | X |
| Login/Logout (Hunt, Ring, UCD) | X | X | X |
| Login/Logout | X | X | X |
| Lunch/Break Mode | X | X | X |
| Memory Back-up | X | X | X |
| Message Waiting—Proprietary Phones | X | X | X |
| Message Waiting SLT | X | X | |
| Military Time Display | X | X | X |
| M.O.H. (Music on Hold) | X | X | X |
| Multi-Cell Wireless | X | X | X |
| Multilingual Displays (5) | X | X | X |
| Multiple Voice Mail Lamps | X | X | X |
| Off-Hook Tone Signaling | X | X | X |
| Off-Hook Monitoring (KX-T7431, 7433, 7436, 7600 Series) | X | X | X |
| Off-Hook Voice Announce (KX-T7235, T7436, 7600 Series) | X | X | X |
| On-Site Programming Diagnostics | X | X | X |
| Operator Call | X | X | X |
| Power Failure Transfer | X | X | X |
| KX-TDA DIGITAL HYBRID IP-PBX SYSTEM FEATURE LIST | |||
|---|---|---|---|
| System Features | KX-TDA50 | KX-TDA100 | KX-TDA200 |
| Pre-Selection (Central Office or Intercom) | X | X | X |
| Privacy Release | X | X | X |
| Remote Programming and Diagnostics | X | X | X |
| Remote Station Lock Control | X | X | X |
| Ring Groups | X | X | X |
| Ring Groups DISA | X | X | X |
| Ringing Line Preference | X | X | X |
| Saved Number Redial | X | X | X |
| Secret Dialing | X | X | X |
| Seven Day ARS Time Tables | X | X | X |
| S.M.D.R. (Station Message Detail Recording) | X | X | X |
| Station Name Display | X | X | X |
| Station to Station Messaging | X | X | X |
| Station Speed Dial Numbers (10) | X | X | X |
| System Speed Dial Numbers | X | X | X |
| TAPI Compliant | X | X | |
| T1 Interface | X | X | |
| T.A.F.A.S. (Trunk Answer from any Station) | X | X | X |
| Toll Restriction | X | X | X |
| Toll Restriction Override | X | X | X |
| Tone/Pulse Conversation | X | X | X |
| Tone/Pulse Dialing (By CO Line) | X | X | X |
| Transfer (Screened/Unscreened) | X | X | X |
| Trunk Groups | X | X | X |
| Two-Way Record (DPITS) | X | X | X |
| Two-Way Transfer (DPITS) | X | X | X |
| Unattended Conference Call | X | X | X |
| Uniform Call Distribution without OGM | X | X | X |
| Uniform Call Distribution with OGM | X | X | X |
| Voice Mail, Automatic Configuration (DPITS only) | X | X | X |
| Voice Mail Integration (Inband) | X | X | X |
| Voice Mail Integration (DPITS) | X | X | X |
| Voice Mail Ports | X | X | X |
| VOIP Gateway | X | X | X |
| VOIP Extension | X | X | |
| Walking Class of Service | X | X | X |
| Whisper OHCA | X | X | X |
| KX-TDA100 & KX-TDA200 POWER SUPPLY | |||||
|---|---|---|---|---|---|
| It is necessary to select the proper power supply for the system in accordance with the type and number of extensions that are connected to the system. There are 3 power supply options; S = Small, M = Medium and L = Large. To calculate the size of the power supply required for your application, you must determine the type of telephone extensions you plan to use. Then using the telephone equipment power factor “B” portion of the chart below, calculate the point value for each and add up all the points. Using the Power Supply Maximum Power Factor “A” portion of the chart below, match up the points calculated with the correct power supply. The power supply value must be greater than the total points calculated for the telephone equipment. (When in doubt use the larger power supply.) | |||||
|
A - Power Supply Maximum Power Factors |
|||||
|
TDA100 |
TDA200 |
||||
|
Power Supply Model |
KX-TDA0108 (S Type) |
KX-TDA0104 (M Type) |
KX-TDA0104 (M Type) |
KX-TDA0103 (L Type) |
|
|
Maximum Power Factor |
64 |
128 |
128 |
512 |
|
|
B - Telephone Equipment Power Factor |
|||||
|
Telephone Equipment |
Point Value For Each |
||||
|
T7600 Digital Series (KX-TDA Digital System Phones) |
1 |
||||
|
KX-T7400 & KX-T7200 Digital Series (KX-TD Digital System Phones) |
4 |
||||
|
KX-T7000, KX-T7300, KX-T7700 Series and DSS Consoles (KX-T & KX-TA Hybrid System Phones) |
4 |
||||
|
SLT* Cards
(Single Line Telephones) |
SLC8 |
8 |
|||
|
SLC16 |
16 |
||||
|
MSLC16 |
16 |
||||
|
DHLC8 |
8 |
||||
|
Cell Station (KX-TDA0142, KX-T0141) |
4 |
||||
|
KX-TVS Voice Mail Port Connection (2 ch) |
1 |
||||
| * Calculation must be based on the number of cards, not the number of telephones. | |||||
CHART #2
|
KX-TDA100 & KX-TDA200 SYSTEM CAPACITIES |
||||||||||||||
|
Category |
Model Name |
Abbreviated as |
Description |
Required Slots |
Connection Capacity |
Card Capacity |
||||||||
|
CO |
SLT |
APT |
DPT |
IP |
Total |
TDA100 |
TDA200 |
|||||||
|
Control Unit |
KX-TDA100 |
— |
Basic Shelf |
— |
— |
— |
— |
— |
— |
— |
— |
— |
||
|
KX-TDA200 |
— |
Basic Shelf |
— |
— |
— |
— |
— |
— |
— |
— |
— |
|||
|
Main Processor Card |
MPR |
Main Central Processing Unit Circuit Card |
1 |
— |
— |
— |
— |
— |
— |
1 |
1 |
|||
|
MPR Option Card |
KX-TDA0196 |
RMT |
Remote Maintenance Trunk Card |
— |
— |
— |
— |
— |
— |
— |
1 |
1 |
||
|
Extension Card |
KX-TDA0170 |
DHLC8 |
8-Port Digital Hybrid |
1 |
— |
8 |
8 |
*8 |
— |
16 |
4 |
8 |
||
| Line Circuit Card | 8 | 8 | *16 | *24 | ||||||||||
|
KX-TDA0172 |
DLC16 |
16-Port Proprietary |
1 |
— |
— |
— |
16 |
— |
16 |
|||||
| Line Circuit Card | *32 | *32 | ||||||||||||
|
KX-TDA0171 |
DLC8 |
8-Port Proprietary |
1 |
— |
— |
— |
8 |
— |
8 |
|||||
| Line Circuit Card | *16 | — | *16 | |||||||||||
| KX-TDA0175 | MSLC16 |
16-Port SLT with
Message Waiting Card Lamp Circuit |
1 | 16 | — | — | — | — | 16 | |||||
| KX-TDA0173 | SLC8 | 8-Port SLT Circuit Card | 1 | 8 | — | — | — | — | 8 | |||||
|
KX-TDA0174 |
SLC16 |
16-Port SLT Circuit Card |
1 |
— |
16 |
— |
— |
— |
16 |
|||||
|
KX-TDA0470 |
IP EXT 16 |
16-Port IP Extension Card |
1 |
— |
— |
— |
— |
16 |
— |
4 |
8 |
|||
|
KX-TDA0143 |
CSIF4 |
4-Port Cell Station Interface Circuit Card |
1 |
— |
— |
— |
— |
— |
— |
4 |
8 |
|||
|
KX-TDA0144 |
CSIF8 |
8-Port Cell Station Interface Circuit Card |
1 |
— |
— |
— |
— |
— |
— |
2 |
4 |
|||
|
Trunk Card |
KX-TDA0180 | LCTOT8 |
8-Port Loop |
1 | 8 | __ | __ | __ | __ | 8 | ||||
|
KX-TDA0181 |
LCOT16 |
16-Port Loop |
1 |
16 |
— |
— |
— |
— |
16 |
4 |
8 |
|||
|
KX-TDA0193 |
CID8 |
Caller ID Card (8 ports) |
— |
— |
— |
— |
— |
— |
— |
8 |
16 |
|||
| KX-TDA0187 | T1 | T1 Line Trunk Card | 1 | 24 | — | — | — | — | 24 | |||||
|
KX-TDA0290 |
PRI23 |
ISDN Primary Rate Access Interface 23 Card |
1 |
23 |
— |
— |
— |
— |
23 |
2 |
4 |
|||
|
KX-TDA0484 |
IP-GW4 |
4-Port IP-Gateway Circuit Card |
1 |
4 |
— |
— |
— |
— |
4 |
2 |
4 |
|||
|
KX-TDA0490 |
IP-GW16 |
16-Port IP-Gateway Circuit Card |
1 |
4 |
— |
— |
— |
— |
4 |
2 |
4 |
|||
|
Optional Card |
KX-TDA0105 |
MEC |
Memory Expansion Circuit Card |
1 |
— |
— |
— |
— |
— |
— |
This card mounts on MPR Card. See MEC Requirement Chart #7 |
|||
| KX-TDA0190 | OPB3 |
Option Base 3
Circuit Card |
1 | — | — | — | — | — | — |
This card is the base for mounting maximum of three option cards (MSG4, DPH4 and ECHO16) |
||||
|
Mounted on the OPB3 card. |
TDA0191 |
MSG4 |
Message Circuit Card |
— |
— |
— |
— |
— |
— |
— |
2 |
4 |
||
| TDA0161 | DPH4 |
Doorphone
Circuit Card |
— | — | — | — | — | — | — | 2 | 4 | |||
| TDA0166 | ECHO16 |
16-Port Echo
Cancelling Circuit Card |
— | — | — | — | — | — | — | 2 | 4 | |||
| TDA0164 | EIO 4 | External I/O Card | — | — | — | — | — | — | — | 2 | 4 | |||
|
KX-TDA0410 |
CTI-LINK |
CTI-LINK Card |
1 |
— |
— |
— |
— |
— |
— |
1 |
1 |
|||
|
Power Supply Unit |
KX-TDA0108 |
PSU-S |
S-Type Power Supply Unit |
— |
— |
— |
— |
— |
— |
— |
For KX-TDA100 |
|||
|
KX-TDA0104 |
PSU-M |
M-Type Power Supply Unit |
— |
— |
— |
— |
— |
— |
— |
For KX-TDA100/ KX-TDA200 |
||||
|
KX-TDA0103 |
PSU-L |
L-Type Power Supply Unit |
— |
— |
— |
— |
— |
— |
— |
For KX-TDA200 |
||||
|
|
||||||||||||||
CHART #3
| KX-TDA100 & KX-TDA200 PORT CAPACITY | ||||
| KX-TDA100 | KX-TDA200 | |||
|
Max. Total Port (Extension + Trunk) |
96* | 192** | ||
|
Max. Extension Port |
64 | 128 | ||
|
|
Propietary Telephone |
64/128 DXDP |
128/256 DXDP |
|
|
SLT (Analog Telephone) |
64 | 128 | ||
|
IP Telephones |
64 | 128 | ||
|
|
Max. Trunk Port |
64 | 128 | |
|
Max. CO (PSTN) |
64 | 128 | ||
|
Max. T1 |
2 (48-ch) |
4 (96-ch) |
||
|
Max. PRI-ISDN (23B) |
2 (46-ch) |
4 (92-ch) |
||
|
Internal PRI (23B) |
2 (46-ch) |
4 (92-ch) |
||
|
Max. IP Gateway (IP-GW4) |
2 (8-ch) |
4 (16-ch) |
||
|
Max. IP Gateway (IP-GW16 |
2 (24-ch) |
4 (48-ch) |
||
|
Accessory Capacities |
||||
|
TDA100 |
TDA200 |
|||
|
Max. CS (Cell Station) |
16 |
32 |
||
|
Max. 2.4GHz Wireless Telephone Handsets |
128 |
128 |
||
|
Max. Doorphones |
8 |
16 |
||
|
Max. Door Openers |
8 |
16 |
||
|
Max. Voice Message (OGM) Channels |
8 |
16 |
||
|
Max. Voice Processing Systems |
2-VPS unit |
2-VPS unit |
||
|
BGM/MOH (Music on Hold) Inputs |
2 |
2 |
||
|
External Paging Outputs |
2 |
2 |
||
|
RS232C/SMDR Outputs |
1 |
1 |
||
|
USB |
1 |
1 |
||
|
Ethernet (10 BaseT) for CTI/Programming |
1 |
1 |
||
|
* The standard total is 80 channels (16 ch/slot x 5) However, the maximum total is 96 channels if 2 T1 cards are mounted |
** The standard total is 160 channels (16 ch/slot x 10) However, the maximum total is 192 channels if 4 T1 cards are mounted |
|||
| KX-TDA100 & KX-TDA200 CARD CAPACITY | |||
|---|---|---|---|
| TDA100 | TDA200 | ||
| Extension Card | DHLC8 | Max. 4 Cards | Max. 8 Cards |
| DLC8, DLC16 | Max. 4 Cards | Max. 8 Cards | |
| SLC8, SLC16 | Max. 4 Cards | Max. 8 Cards | |
| IP-EXT16 | Max. 4 Cards | Max. 8 Cards | |
| CSIF4 | Max. 4 Cards | Max. 8 Cards | |
| CSIF8 | Max. 2 Cards | Max. 4 Cards | |
| Trunk Card | LCOT8, LCOT16 PRI, T1 | Max. 4 Cards | Max. 8 Cards |
| IP-GW4 & IP-GW16 | Max. 2 Cards | Max. 4 Cards | |
| Option Card | OPB3, CTI-LINK | Max. 2 Cards | Max. 4 Cards |
|
KX-TDA50 CAPACITIES |
|||||
|---|---|---|---|---|---|
|
MAXIMUM NUMBER/CABINET |
|||||
|
TDA50 |
TDA50 | ||||
|
with included |
with Optional |
||||
|
AC Adapter |
AC Adapter | ||||
| TRUNK & EXTENSION | |||||
|
|
Trunk Port |
8 | 8 | ||
| Analog Trunk | 8 | 8 | |||
|
Extension Port |
28 | 28 | |||
|
Single Line Telephone |
24 | 24 | |||
|
Analog Proprietary Telephone and DSS Console |
4 | 24 | |||
|
Digital Proprietary Telephone (Type 1)3 |
24/48 DXDP |
24 | |||
|
Digital Proprietary Telephone (Type 2)2 |
4 | 24 | |||
|
Cell Station (KX-TDA0141) |
4 | 8 | |||
|
Voice Processing System |
4 (1 System) |
4 (1 System) | |||
| Wireless Telephone Handsets (KX-TD7680 and KX-TD7690) | 28 | 28 | |||
| Doorphones (KX-T30865) | 4 | 4 | |||
| 1Optional AC Power Supply KX-A236 required to accommodate this configuration | |||||
| 2Type2: T7200 and T7400 Series (KX-TD Digital System Phones) | |||||
| 3Type1: T7600 Series (KX-TDA Digital System Phones) | |||||
| 4Limited to 8 Max DPT(Type2) + APT + CS | |||||
|
KX-TDA 50/100/200 SYSTEM SPECIFICATIONS |
||||||||
|---|---|---|---|---|---|---|---|---|
| Switching: Non Blocking Distributed Time Switch | ||||||||
| Power Source: AC120v 60Hz | ||||||||
|
Wiring:
SLT: One Pair (T,R) APT: 2 Pair (T,R,D1,D2) |
||||||||
|
Certification No:
TDA100/200
ACJMF03AKX-TDA100
TDA50 ACJMF03AKX-TDA50 |
||||||||
| Ringer Equivalence No: 0.3A | ||||||||
| Facility Interface Code: 02LS2, 04DU9.BN/DN/1KN/1SN, METALLIC | ||||||||
| Service Order Code: 9.0F, 6.0P | ||||||||
|
Dimensions: KX-TDA50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . .. . . . . . . . . . .. . . . . . . . . . . . (10-3/4 in x 14-3/4 in x 4-5/8 in) KX-TDA100 . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . (13-1/3 in x 15-3/5 in x 10-4/5 in) KX-TDA200 . . . . . . . .. . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . .. . . . . . . . . . . . . (17-1/5 in x 16-3/5 in x 10-4/5 in) |
|
|||||||
|
Operating Environment:
Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . .. . . . . . . . . . . . . 0 °C to 40 °C (32 °F to 104 °F) Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . .. . . . . . . . . . . . . . 10 % to 90 % (non condensing) |
||||||||
|
Consumption
KX-TDA50 with Main PS . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . .. . . . . . (100 V AC to 240 V AC, 1.5 A, 50Hz/60Hz) KX-TDA50 with Main + Optional PS . . . . . . . . . . . ... . . . . . . . . . .. . . . . (100 V AC to 240 V AC, 3.0 A, 50 Hz/60 Hz) KX-TDA100 with PSU-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . 210 W, 2.2 A (at 120 V AC, 60 Hz) KX-TDA200 with PSU-M . . . . . . . . . . . . . . . . . . . .. .. . . . . . . . . . .. . . . . . . . . . . . 240 W, 2.5 A (at 120 V AC, 60 Hz) KX-TDA200 with PSU-L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . 490 W, 5.1 A (at 120 V AC, 60 Hz) |
||||||||
|
KX-TDA 50/100/200 MEMORY EXPANSION CARD (MEC ) REQUIREMENTS |
|||||
|---|---|---|---|---|---|
| The memory expansion card (KX-TDA5105) for the KX-TDA50 and the memory expansion card (KX-TDA0105) for the KX-TDA100/200 required when the following features are used. | |||||